SureSigns VM1

Vital signs monitor

Bekijk soortgelijke producten

Philips SureSigns VM1 is a cost-effective, easy to use, and easy to support patient monitor. Designed for adult, pediatric, and neonatal patients, it offers SpO₂, heart rate with options for CO₂, and key respiratory measurement parameters.

Technische specificaties

SureSigns VM1 monitor
SureSigns VM1 monitor
monitor width
  • 26.0/10.2 cm/"
monitor height
  • 9.0/3.5 cm/"
monitor depth
  • 23/9.1 cm/"
monitor weight
  • including optional CO₂ module and recorder: 1.82/4.0 kg/lbs
screen
  • WQVGA TFT-AM LCD display: 10.9 cm/4.3"
SpO₂
  • Measurement Range: 0 to 100 Accuracy depends on sensor. Heart rate measurement range: 30 to 300 bpm. Heart rate accuracy ± 2% or ± 1 bpm whichever is greater. Complies with EN ISO 9919 standard %
CO₂ (optional)
  • Microstream technology. Measurement range: 0 to 150 mmHg.Accuracy: 0 - 38 mmHg, ± 2 mmHg. 39 - 99 mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) 100 - 150 ± mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) mm Hg
Battery
  • Internal lithium ion 10.8 to 11.1 V. Operating time: 6 hours with continuous SpO₂ measurements every 4 hours
Data output
  • HL7 format via Ethernet port. USB port. Optional serial interface adapter
Patient type
  • Adult/Pediatric/Neonatal
Display modes
  • large numeric display numeric and waveform display tabular trend display graphical trend display
Respiration measurement
  • 0-150 rpm
Respiration accuracy
  • ±1rpm in the range of 0-70rpm   ±2rpm in the range of 71-120rpm ±3rpm in the range of 121-150rpm rpm
Recorder Type (optional)
  • Paper width: 58mmSpeed: 6.25mm, 12.5mm, 25mm, and 50mm/sec; user selectable
SureSigns VM1 monitor
SureSigns VM1 monitor
monitor width
  • 26.0/10.2 cm/"
monitor height
  • 9.0/3.5 cm/"
Bekijk alle specificaties
SureSigns VM1 monitor
SureSigns VM1 monitor
monitor width
  • 26.0/10.2 cm/"
monitor height
  • 9.0/3.5 cm/"
monitor depth
  • 23/9.1 cm/"
monitor weight
  • including optional CO₂ module and recorder: 1.82/4.0 kg/lbs
screen
  • WQVGA TFT-AM LCD display: 10.9 cm/4.3"
SpO₂
  • Measurement Range: 0 to 100 Accuracy depends on sensor. Heart rate measurement range: 30 to 300 bpm. Heart rate accuracy ± 2% or ± 1 bpm whichever is greater. Complies with EN ISO 9919 standard %
CO₂ (optional)
  • Microstream technology. Measurement range: 0 to 150 mmHg.Accuracy: 0 - 38 mmHg, ± 2 mmHg. 39 - 99 mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) 100 - 150 ± mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) mm Hg
Battery
  • Internal lithium ion 10.8 to 11.1 V. Operating time: 6 hours with continuous SpO₂ measurements every 4 hours
Data output
  • HL7 format via Ethernet port. USB port. Optional serial interface adapter
Patient type
  • Adult/Pediatric/Neonatal
Display modes
  • large numeric display numeric and waveform display tabular trend display graphical trend display
Respiration measurement
  • 0-150 rpm
Respiration accuracy
  • ±1rpm in the range of 0-70rpm   ±2rpm in the range of 71-120rpm ±3rpm in the range of 121-150rpm rpm
Recorder Type (optional)
  • Paper width: 58mmSpeed: 6.25mm, 12.5mm, 25mm, and 50mm/sec; user selectable
  • * Not available in all markets