SureSigns VS4

Vital signs monitor

Bekijk soortgelijke producten

Expand vital signs monitoring with Philips SureSigns VS4. Respond to changing patient conditions by choosing between frequent vitals and spot check mode. Prompt urgent action with QuickAlerts and simplify workflow with QuickCapture and QuickCheck tools.

Kenmerken
Bright, color backlit screen

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.
Philips SpO2 technology

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.
  • Bright, color backlit screen
  • Philips SpO2 technology
Bekijk alle kenmerken
Bright, color backlit screen

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.
Philips SpO2 technology

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Technische specificaties

SureSigns VS4
SureSigns VS4
Dimensions
  • 26 (10.2) x 22 (8.6) x 14.5 (5.7) Cm/in.
Weight
  • 3.1 (6.9) – exluding optional recorder Kg/lb
Screen
  • 8.4 inch SVGA TFT-AM LCD display, 800 active pixels/line; resolution: 600 active lines/frame; viewing angle ±60 degrees
Stepwise deflation pressure (Adult)
  • Diastolic: 10-245 (1.3-32.7); Systolic: 30-270 (4.0-36.0); MAP: 20-255 (2.7-34.0) mmHg/kPa
Stepwise deflation pressure (Pediatric)
  • Systolic: 30-180 (4.0-24.0); Diastolic: 10-150 (1.3-20.0); MAP: 20-160 (2.7-21.3) mmHg/kPa
Stepwise deflation pressure (Neonatal)
  • Systolic: 30-130 (4.0-17.0); Diastolic: 10-100 (1.3-13.3); MAP: 20-120 (2.7-16.0) mmHg/kPa
NBP measurement accuracy
  • Maximum standard deviation: 8 mmHg; Maximum mean error: ±5mmHg
Subsequent cuff inflation (in NBP interval mode only)
  • The subsequent inflation pressure is determined automatically, depending on the previous measurement and patient type
SpO2 measurement range
  • 0-100%; pulse rate measurement range 30-300 pbm. Accuracy depends on sensor
SpO2
  • Meets EN ISO 9919 standard
Welch Allyn Predictive Temperature
  • Probe Sites: Oral, rectal, axillary; Range 26.7-43.3°C (80-110°F); Accuracy ±0.1°C (±0.2°F) in monitoring mode
Covidien Tympanic Temperature
  • Equivalency modes: ear (no adjustment), oral (adjusted from ear), core (adjusted from ear), rectal (adjusted from ear)
Covidien Tympanic Temperature
  • Range: 33°C-42°C (91.4°F-107.6°F) s
  • Accuracy (overall range): ±0.2°C (±0.4°F) s
  • Measurement response time: ≤2 s
Battery
  • Lithium ion: 10.8-11.1V (with a “202” form factor)
Data Output
  • HL7 format, via Ethernet port; serial data
Patient type
  • Adult, pediatric, neonatal
SureSigns VS4
SureSigns VS4
Dimensions
  • 26 (10.2) x 22 (8.6) x 14.5 (5.7) Cm/in.
Weight
  • 3.1 (6.9) – exluding optional recorder Kg/lb
Bekijk alle specificaties
SureSigns VS4
SureSigns VS4
Dimensions
  • 26 (10.2) x 22 (8.6) x 14.5 (5.7) Cm/in.
Weight
  • 3.1 (6.9) – exluding optional recorder Kg/lb
Screen
  • 8.4 inch SVGA TFT-AM LCD display, 800 active pixels/line; resolution: 600 active lines/frame; viewing angle ±60 degrees
Stepwise deflation pressure (Adult)
  • Diastolic: 10-245 (1.3-32.7); Systolic: 30-270 (4.0-36.0); MAP: 20-255 (2.7-34.0) mmHg/kPa
Stepwise deflation pressure (Pediatric)
  • Systolic: 30-180 (4.0-24.0); Diastolic: 10-150 (1.3-20.0); MAP: 20-160 (2.7-21.3) mmHg/kPa
Stepwise deflation pressure (Neonatal)
  • Systolic: 30-130 (4.0-17.0); Diastolic: 10-100 (1.3-13.3); MAP: 20-120 (2.7-16.0) mmHg/kPa
NBP measurement accuracy
  • Maximum standard deviation: 8 mmHg; Maximum mean error: ±5mmHg
Subsequent cuff inflation (in NBP interval mode only)
  • The subsequent inflation pressure is determined automatically, depending on the previous measurement and patient type
SpO2 measurement range
  • 0-100%; pulse rate measurement range 30-300 pbm. Accuracy depends on sensor
SpO2
  • Meets EN ISO 9919 standard
Welch Allyn Predictive Temperature
  • Probe Sites: Oral, rectal, axillary; Range 26.7-43.3°C (80-110°F); Accuracy ±0.1°C (±0.2°F) in monitoring mode
Covidien Tympanic Temperature
  • Equivalency modes: ear (no adjustment), oral (adjusted from ear), core (adjusted from ear), rectal (adjusted from ear)
Covidien Tympanic Temperature
  • Range: 33°C-42°C (91.4°F-107.6°F) s
  • Accuracy (overall range): ±0.2°C (±0.4°F) s
  • Measurement response time: ≤2 s
Battery
  • Lithium ion: 10.8-11.1V (with a “202” form factor)
Data Output
  • HL7 format, via Ethernet port; serial data
Patient type
  • Adult, pediatric, neonatal
  • Welch Allyn & SureTemp are registered trademarks of Welch Allyn
  • Masimo, SET, and rainbow are registered trademarks of Masimo Corporation